Hybrid Ultra

The ICT Hybrid Ultra combines a 48 or 24 volt DC power system with a factory installed 12 or 24 volt DC converter module to provide up to 7,500 watts of maximum power for a flexible hybrid DC solution for wireless network sites. The Hybrid Ultra accepts up to five hot swappable 48 or 24 volt, 700 watts or 1500 watts DC Power Modules. The integrated DC converter provides up to 700 watts of 12 or 24 volts DC output through a separate output bus bar.

FEATURES

  • Up to five 700-watts or 1500-watts, 48- or 24-volt DC system power modules
  • Total maximum total output power 7,500 watts
  • Integrated 700-watt 12-or 24-volt DC power converter
  • Dual 100-amp battery disconnect breakers
  • Integrated 150-amp low voltage disconnect with adjustable setpoints
  • Four or eight fully managed load distribution outputs (25 A max. each)
  • 90 to 95% efficiency
  • –30°C to +60°C operating temperature range
  • Standard TCP/IP Ethernet communications provides full remote monitoring and control capabilities
  • Network security protocols include HTTPS, TLS 1.2, SNMP v1/v2c/v3
  • User adjustable output voltages and battery charge current limit
  • Advanced battery management features including state of charge, estimated run-time remaining, battery discharge testing, temperature compensated charging
  • Alarm reporting via text or email notification
  • Battery temperature and site monitoring input contacts
  • 2RU 19-inch rackmount form factor
  • Support for lead-acid and lithium-ion battery types
  • Two-year warranty

 

BENEFITS

  • Configurable DC power system provides flexibility and scalability to meet application requirements
  • Integrated 700-watt DC-DC power module provides a secondary voltage for sites with mixed voltages requirements – 48 & 24 or 48 & 12 VDC
  • Reduce total cost of ownership by reducing site visits and maintenance costs due to remote monitoring and control functionality
  • Improve the quality of service and uptime of your network by quickly resolving power issues remotely
  • User-scheduled battery testing proactively alerts users when a connected backup battery is not holding charge
  • Real-time reporting on battery state of charge, battery run-time remaining, and battery voltage levels
  • Remotely monitor and toggle power to individually connected load devices utilizing load distribution module
  • All connection points are external, allowing for quick and easy installation
  • No additional software required as monitoring and control is provided via an onboard web-based server

 

Description

AC Input

Nominal System Voltage 120/240/VAC
Input Voltage Range 100-300-VAC
Power Factor (typical) 0.99
Frequency 50/60Hz


1,500W Power Modules

Model Number ICT1500-48PM ICT1500-24PM
Nominal Voltage 48 24
Output Voltage Range (adjustable) 46.0 – 62.0 VDC 23.0 -31.0 VDC
Output Current per Module (230VAC nom.) 27A 54A
Output Current per Module (115VAC nom.) 16A 32A
Power Factor 0.99 typ. 0.99 typ.
Efficiency (typical) 95% 94%
Output Ripple (rms) 60mV 40mV


700W Power Modules

Model Number ICT700-48PM ICT700-24PM
Nominal Voltage 48 24
Output Voltage Range (adjustable) 46.0 – 62.0 VDC 23.0 -31.0 VDC
Output Current per Module 12.5A 25A
Power Factor 0.99 typ. 0.99 typ.
Efficiency (typical) 93% 91%
Output Ripple (rms) 60mV 30mV


DC Converter

Power Output 700W 700W
Nominal Voltage 13.8 27.6
Output Voltage Range (adjustable) 11.5 – 15.5 VDC 23.0 – 31.0 VDC
Output Current per Module 50A 25A
Power Factor 0.99 typ. 0.99 typ.
Efficiency (typical) 92% 92%
Output Ripple (rms) 20mV 30mV
AC Input Connectors (dual) Terminal Block, #8 – #16 AWG
DC Output Connector Busbars with 1/4-20 x 7/8” bolts
Ethernet Connector RJ-45
Remote Alarm Connectors Terminal Block (#16 – 24 AWG)
Mounting 2RU, 19 inch rack mount
Weight (exc. Power Modules) 30lbs / 13.6 kg
Dimensions – H x W x L 3.5 x 19.0 x 15.7 in.

89 x 483 x 398 mm

Operating Temperature Range -30°C to +60°C
Output Derating 2% / °C (above 50° C)
Storage Temperature -45° to +85° C
Safety EN 60950-1
Emissions (48/24V only) EN61000-6-1. EN61000-6-3. EN61000-3-2, RoHS, CE
Load Outputs 12 or 8
Over Current Protection Hydraulic/magnetic circuit breakers
Max. Breaker Size 30A
Front Display High resolution OLED with function keys
Remote Communications TCP/IP 10/100 Base-T
I.P. Protocols HTTP/HTTPS, SMTP, SNMPv1/v2/v3
Inputs 4 digital, 1 analog temp sensor contacts
Battery Circuit Breaker Dual 100A
Low Voltage Disconnect 150A contactor
Two year warranty

Hybrid Ultra Data Sheet

800-351-005

1500 Watt DC Power Module Data Sheet

800-345-005

Title